Seametrics® Insertion Electromagnetic Flow Sensor, 316SS Hot Tap & body, 3"-10" pipe, EX150S-08
Description
The Seametrics® EX150S-08 hot tap, adjustable depth insertion magmeter flow sensor can measure clean or turbid water. The complete lack of moving parts make it very reliable. Installation requires 2" FNPT threaded fitting such as a pipe saddle. Includes a 2" MNPT 316SS isolation valve for hot-tap applications for installation and removal under pressure. Pulse output can interface with PLC or use with a Seametrics FT-Series Flow Monitor/Totalizer for flow rate/total display and optional 4-20mA output.
Features
- Reliable, no moving parts
- Depth adjustable sensor
- Meter extends only about 1/8 of pipe diameter, minimizing potential clogging with debris
- Use SS model for potable water applications
- Use for "full pipe" applications
- Use with FT430 or FT440 Monitor/Totalizers
Product Specifications
Sensor Cable Length UOM | FT |
Input | 5V pulse or contact closure |
Power | 12-25 VDC, 250 mA minimum |
Fitting Size | 2" |
Conductivity | 20 |
Output | (2) Pulse Outputs, Opto-Isolated |
Pressure Max (PSI) | 200 |
Brand | Seametrics |
Conductivity UOM | uS |
Fitting Size Type | FNPT |
Empty Pipe Detection | Y |
Accuracy | 1% of full scale |
Sensor Cable Length | 18 |
Pulse Output | (2) Pulse Outputs, Opto-Isolated |
Documents