Designed for water quality experts, the Hach HQ440D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD meters connect with smart IntelliCALⓇ electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD meters feature a simple user interface that does not require manuals or training to operate. The IntelliCAL PHC281 is a standard combination pH electrode, robust plastic body, refillable with built-in temperature sensor and 1 m cable. PHC281 is intended for laboratory use and specially designed for fast response and stabilisation to measure pH in general purpose water quality applications or in difficult samples such as low ionic strength (LIS), ultrapure, dirty, TRIS, or high-solid content samples. The IntelliCAL CDC401 with 1 m cable CDC401 is a digital, graphite, 4-pole conductivity electrode, ideal for measuring electrical conductivity, salinity, resistivity, or total dissolved solids (TDS) in wastewater, drinking water, or general water quality applications. The IntelliCAL LDO101 is a digital, luminescent/optical dissolved oxygen (LDO) electrode. The standard version is intended for laboratory use. The LDO101 is ideal for measuring dissolved oxygen in wastewater, drinking water and general water quality applications.
- Two input channels for simultaneous measurement of pH, Conductivity, Total Dissolved Solid (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Oxydo Reduction Potential (ORP/RedOx),
- Guided calibration and check standard routines reduce calibration errors while stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results.
- Calibration history allows quick and easy change out of probes without re-calibrating.
PC software | HQd Series Meter Data Transfer Utility |
Display | Detailed mode/Large mode |
Calibration Intervals/Alerts/Reminder | Off, selectable from 2 hours to 7 days |
Casing IP Rating | IP54 (Resistant to spray of water; Dust-proof) |
Barometric Pressure Measurement | Automatic compensation of DO when using an LDO or LBOD probe |
Auto-Buffer Recognition | Yes |
Display Lock Function | Continuous / Auto-stabilization ("press to read") / At Interval |
Sensors | Sensor A: PHC28101 Sensor B: CDC40101 Sensor C: LDO10101 |
DO Electrode Calibration | 100% (water-saturated air (100%) calibration |
Communication | Integrated USB type A and Integrated USB type B (for PC) |
CDC Electrode Calibration | Demal (1D/ 0.1D/ 0.01D); Molar (0.1M/ 0.01M/0.001M); NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm); |
Conductivity Measurement | 0.01 µS/cm - 200.0 mS/cm |
Data Export | Download via USB connection to PC or flash memory device. |
Conductivity Resolution | 0.01 µS/cm - 0.1 mS/cm upon selected measuring range |
Custom Calibration Standards | Yes |
ISE Direct Measurement | Yes |
Data Storage | Automatic, GLP ISO compliant reading data stored with calibration details. |
DO Resolution | 0.1 |
Electrode Stand | Included |
DO Measurement | 0.1 - 20.0 mg/L (ppm) 1 - 200% saturation |
GLP features | Date; Time; Sample ID; Operator ID |
Temperature Resolution | 0.1 |
TDS Measurement | 0.00 mg/L - 50.0 g/L as NaCl |
TDS Resolution | 0.01 mg/L - 0.1 g/L upon measuring range. |
ISE Electrode Calibration | 2 - 5 points |
Instrument | Bench |
Weight | 16.4500 |
Simultaneous Measurements | Yes |
Sensor A | PHC28101 |
Sensor B | LDO10101 |
Sensor C | CDC40101 |
Salinity Resolution | 0.01 (ppt) (‰) |
Salinity Measurement | 0 - 42 (ppt) (‰) |
Resistivity Measurement | 2.5 Ω.cm - 49 MΩ.cm |
Resistivity Resolution | 0.1 |
Probes Included? | PHC28101, CDC40101, LDO10101 |
Printer | Yes, Optional |
Measurement Method | Probe specific programmed method settings |
pH Measurement Range | 0 - 14 pH |
pH Electrode Calibration | 1 - 3 Calibration points Calibration summary data logged and displayed |
pH Resolution | Selectable: 0.001/0.01/0.1 pH |
Contents | Meter + Probe(s) + Lab. Accessories + Reagents |
pH Buffer Sets | Color-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH |
ORP Electrode Calibration | Predefined ORP standards (including Zobell's solution) |
Operating Interface | Soft Touch Keypad |
Needed Cable Length | 1 |
mV Resolution | 0.1 mV |
mV Measurement at Stable Reading | Yes |
Temperature compensation | Automatic Temperature compensation for pH |
Temperature range | -10°C - 110 °C |
Parameters | pH/ORP, Conductivity/TDS/Salinity/Resistivity, DO, BOD |
Warranty | 36 months |