Hach HQ440D Laboratory pH Meter Kit w/ RedRod PHC735 Glass Refill Electrode, Dirty Sample, 8505450

$3,882.00 | EA
Product #: 702346
Mfr. Part #: 8505450

Out of Stock - Ships in 5-10 Days

SAVE 15% ON THIS INSTRUMENT WHEN YOU BUNDLE WITH ANY QUALIFYING CHEMISTRY USING CODE HACH15.

Description

Designed for water quality experts, the Hach HQ440D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD digital meters connect with smart IntelliCALⓇ electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD bench meters feature a simple user interface that does not require manuals or training to operate. The IntelliCAL PHC735 is a digital, combination glass-body electrode with a refillable KCl reference and built-in temperature sensor. The PHC735 utilizes Red Rod technology to deliver exceptionally fast response times and stable, accurate measurements. It has a high-flow annular ring junction and is ideal for measuring pH of “dirty samples, including wastewater and food and beverage applications.

Features

  • Two input channels for simultaneous measurement of pH, Conductivity, Total Dissolved Solid (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Oxydo Reduction Potential (ORP/RedOx),

  • Guided calibration and check standard routines reduce calibration errors while stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results.

  • Calibration history allows quick and easy change out of probes without re-calibrating.

Product Specifications

PC software HQd Series Meter Data Transfer Utility
Display Detailed mode/Large mode
Calibration Intervals/Alerts/Reminder Off, selectable from 2 hours to 7 days
Casing IP Rating IP54 (Resistant to spray of water; Dust-proof)
Barometric Pressure Measurement Automatic compensation of DO when using an LDO or LBOD probe
Auto-Buffer Recognition Yes
Display Lock Function Continuous / Auto-stabilization ("press to read") / At Interval
Sensors Sensor A: PHC73501 Sensor B: NA Sensor C: NA
DO Electrode Calibration 100% (water-saturated air (100%) calibration
Communication Integrated USB type A and Integrated USB type B (for PC)
CDC Electrode Calibration Demal (1D/ 0.1D/ 0.01D); Molar (0.1M/ 0.01M/0.001M); NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Conductivity Measurement 0.01 µS/cm - 200.0 mS/cm
Data Export Download via USB connection to PC or flash memory device.
Conductivity Resolution 0.01 µS/cm - 0.1 mS/cm upon selected measuring range
Custom Calibration Standards Yes
ISE Direct Measurement Yes
Data Storage Automatic, GLP ISO compliant reading data stored with calibration details.
DO Resolution 0.1
Electrode Stand Included
DO Measurement 0.1 - 20.0 mg/L (ppm) 1 - 200% saturation
GLP features Date; Time; Sample ID; Operator ID
Temperature Resolution 0.1
TDS Measurement 0.00 mg/L - 50.0 g/L as NaCl
TDS Resolution 0.01 mg/L - 0.1 g/L upon measuring range.
ISE Electrode Calibration 2 - 5 points
Instrument Bench
Weight 10.0000
Simultaneous Measurements Yes
Sensor A PHC73501
Sensor B NA
Sensor C NA
Salinity Resolution 0.01 (ppt) (‰)
Salinity Measurement 0 - 42 (ppt) (‰)
Resistivity Measurement 2.5 Ω.cm - 49 MΩ.cm
Resistivity Resolution 0.1
Probes Included? PHC73501
Printer Yes, Optional
Measurement Method Probe specific programmed method settings
pH Measurement Range 0 - 14 pH
pH Electrode Calibration 1 - 3 Calibration points Calibration summary data logged and displayed
pH Resolution Selectable: 0.001/0.01/0.1 pH
Contents Meter + Probe(s) + Lab. Accessories + Reagents
pH Buffer Sets Color-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH
ORP Electrode Calibration Predefined ORP standards (including Zobell's solution)
Operating Interface Soft Touch Keypad
Needed Cable Length 1
mV Resolution 0.1 mV
mV Measurement at Stable Reading Yes
Temperature compensation Automatic Temperature compensation for pH
Temperature range -10°C - 110 °C
Parameters pH/ORP, Conductivity/TDS/Salinity/Resistivity, DO, BOD
Warranty 36 months

Compliance and Restrictions

Hazardous materials
 California residents see Prop 65 WARNINGS