Hach HQ440D Laboratory Chloride (Cl⁻) Ion Meter Kit w/ ISECL181 Ion Selective Electrode, 8507900

$4,676.00 | EA
Product #: 702359
Mfr. Part #: 8507900

Out of Stock - Ships in 5-10 Days

Description

Designed for water quality experts, the Hach HQ440D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD meters connect with smart IntelliCALⓇ electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD meters feature a simple user interface that does not require manuals or training to operate. The IntelliCAL ISECL181 is a digital, combination chloride ion selective electrode (ISE) with a non-refillable, double junction reference and built-in temperature sensor. The IntelliCAL ISECL181 electrode is intended for laboratory use. The ISECL181 is ideal for measuring chloride concentrations in wastewater, drinking water and general water quality applications. The ISECL181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the electrode.

Features

  • Two input channels for simultaneous measurement of pH, Conductivity, Total Dissolved Solid (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Oxydo Reduction Potential (ORP/RedOx),

  • Guided calibration and check standard routines reduce calibration errors while stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results.

  • Calibration history allows quick and easy change out of probes without re-calibrating.

Product Specifications

Salinity Resolution 0.01 (ppt) (‰)
Salinity Measurement 0 - 42 (ppt) (‰)
DO Resolution 0.1
Electrode Stand Included
DO Measurement 0.1 - 20.0 mg/L (ppm) 1 - 200% saturation
GLP features Date; Time; Sample ID; Operator ID
Resistivity Measurement 2.5 Ω.cm - 49 MΩ.cm
PC software HQd Series Meter Data Transfer Utility
Resistivity Resolution 0.1
Display Detailed mode/Large mode
Temperature Resolution 0.1
Probes Included? ISECL18101
TDS Measurement 0.00 mg/L - 50.0 g/L as NaCl
Printer Yes, Optional
TDS Resolution 0.01 mg/L - 0.1 g/L upon measuring range.
ISE Electrode Calibration 2 - 5 points
Instrument Bench
Measurement Method Probe specific programmed method settings
Calibration Intervals/Alerts/Reminder Off, selectable from 2 hours to 7 days
pH Measurement Range 0 - 14 pH
pH Electrode Calibration 1 - 3 Calibration points Calibration summary data logged and displayed
Casing IP Rating IP54 (Resistant to spray of water; Dust-proof)
pH Resolution Selectable: 0.001/0.01/0.1 pH
Weight 10.0000
Barometric Pressure Measurement Automatic compensation of DO when using an LDO or LBOD probe
Auto-Buffer Recognition Yes
Contents Meter + Probe(s) + Lab. Accessories + Reagents
pH Buffer Sets Color-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH
ORP Electrode Calibration Predefined ORP standards (including Zobell's solution)
Simultaneous Measurements Yes
Operating Interface Soft Touch Keypad
Needed Cable Length 1
Display Lock Function Continuous / Auto-stabilization ("press to read") / At Interval
Sensors Sensor A: ISECL18101 Sensor B: NA Sensor C: NA
mV Resolution 0.1 mV
DO Electrode Calibration 100% (water-saturated air (100%) calibration
Sensor A ISECL18101
mV Measurement at Stable Reading Yes
Temperature compensation Automatic Temperature compensation for pH
Communication Integrated USB type A and Integrated USB type B (for PC)
Temperature range -10°C - 110 °C
CDC Electrode Calibration Demal (1D/ 0.1D/ 0.01D); Molar (0.1M/ 0.01M/0.001M); NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Conductivity Measurement 0.01 µS/cm - 200.0 mS/cm
Data Export Download via USB connection to PC or flash memory device.
Conductivity Resolution 0.01 µS/cm - 0.1 mS/cm upon selected measuring range
Parameters pH/ORP, Conductivity/TDS/Salinity/Resistivity, DO, BOD
Custom Calibration Standards Yes
Sensor B NA
Sensor C NA
Warranty 36 months
ISE Direct Measurement Yes
Data Storage Automatic, GLP ISO compliant reading data stored with calibration details.

Compliance and Restrictions

Hazardous materials
 California residents see Prop 65 WARNINGS