Recommended COD test for very high concentrations in wastewater influent. The Chemical Oxygen Demand analysis provides important information for the water treatment process and is essential to calculate the BOD COD ratio in wastewater. Due to this, the COD is one of the most frequently analyzed wastewater parameters globally. Why should you use Hach TNTplus® COD tests? Hach TNTplus COD vial test reagents are incredibly simple to use and cut down significantly on waste generation compared to other COD test kits. TNT824 is based on Hach Method 10212 for virtually any type of water sample. Hach TNTplus COD vial tests are available in multiple ranges. TNT824 provides a result in the Ultra High Range of 5,000 - 60,000 mg/L COD and is often used for Chemical Oxygen Demand measurement in special industrial wastewater influent. Hach TNT824 does not require a separate blanking vial for further waste reduction and is compatible with our ezCOD Waste Recycling Service for further peace of mind. Make the switch to TNTplus COD reagents today! Method For determination of Chemical Oxygen Demand (COD) by the Reactor Digestion Method. Simply pipette in sample, digest, and read in your Hach Spectrophotometer. 25 tests per box. Recommended instruments: DR3900, DR6000, and DRB200.
- The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
- The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
- The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
- New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
Storage Conditions | 15 - 25 °C (protect from light) |
Number of Tests | 25 |
Method Number | 10212 |
Method Name | Reactor Digestion |
Instrument | DR3900, DR6000, DR1900, DR2800, DR3800, DR5000 |
Ranges | 5,000 - 60,000 mg/L |
Parameters | COD |
Platform | TNT plus™ |
Shelf-Life | 29 months from production date |