Hach 2100Q Portable Turbidimeter, 2100Q01
Description
Measuring and monitoring turbidity is crucial for various industrial and municipalapplications, and Hach’s portable turbidimeter, the 2100Q, provides unsurpassed ease of use and accuracy. With over 80 years of experience, Hach is a leader in turbidity measurement and has consistently developed reliable and durable instruments for customers. The portable 2100Q turbidity meter is ideal for use in the field or around the plant. It is easy to carry around and take multiple measurements from various collection points in your treatment process. With its intuitive user interface, the 2100Q makes it easy to take measurements and perform calibration and verification. Storing and transferring data from a portable turbidimeter has never been easier. There is also an optional USB+Power module for the 2100Q portable turbidimeter, which allows you to transfer your data directly to a computer. The 2100Q portable turbidimeter is compliant with USEPA Method 180.1 design criteria.
Features
- Save time and get accurate results with an easy-to-follow interface that eliminates the need for complicated manuals to perform routine calibrations. Single-standard Rapidcal™ calibration offers a simplified solution for low level measurements, while ensuring you meet reporting requirements.
- Data transfer with the optional USB+Power Module is simple, flexible, and doesn't require additional software. All data can be transferred to the module in XML format and easily downloaded to your computer with a USB connection, providing superior data integrity and availability.
- The innovative Rapidly Settling Turbidity™ mode provides accurate measurements for difficult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.
- Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages, and the result.
- The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, enabling analysts to achieve laboratory-grade performance on a wide range of samples, even under difficult site conditions.
Includes
Instrument, case assembly, 4 AA alkaline batteries, 6 sample cells, Stablcal ampule kit, silicone oil, oiling cloth, manual.
Product Specifications
Battery Requirements | 4, AA |
Repeatability | ± 1 % of reading or 0.01 NTU , whichever is greater |
Data logging | 500 records |
Cuvette Compatibility | 25 mm x 60 mm round |
Storage Conditions | -40 °C to 60 °C |
Interface | No USB and Power Cord |
User Interface | Button Graphic User Interface |
Accuracy | ± 2 % of reading plus stray light |
Light source | Tungsten Filament Lamp |
Max Operating Humidity | 90 % |
Measurement Modes | Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity |
Stray Light | 0.02 NTU |
Signal Averaging | Selectable on/off |
Source Lamp | Tungsten filament lamp |
Sample Requirements | 15 mL (0.5 oz) |
Response Time | 6 s in normal reading mode |
Reading Modes | Normal (Push to Read) Signal Averaging Rapidly Setting Turbidity |
Regulatory | EPA Method 180.1 |
Warranty | 12 months |
Range 2 | NTU |
Power supply | Batteries (see Battery Requirements) or Optional Power Supply |
Sample Volume | 15 mL |