Hach TU5300sc Low Range Laser Turbidimeter w/ System Check, EPA Version, LXV445.99.11112

$3,271.00 | EA
Product #: 703645
Mfr. Part #: LXV445.99.11112

Out of Stock - Ships in 5-10 Days

Description

Compliant with EPA approved Hach Method 10258 and perfect for conventional filtration and other low range turbidity measurements, the TU5300sc employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection Technology in any TU5 Series turbidimeter. The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. With a 10mL sample size, response time is over 15 times faster than a 1720E. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. With a mounting pattern identical to the 1720E, replacing your previous turbidimeter is fast and simple. All of this, along with the ability to measure to 0.002 NTU, gives you the next standard in the evolution of turbidity. Ensure that your turbidimeter is always functioning properly with this TU5's System Check capability. With the ability to provide information on measurement status and vial cleanliness, you can have full confidence in your turbidity measurement.

Features

  • The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.

  • For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection™ Technology in both instruments.

  • The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.

  • Prognosys™ monitors your TU5 Series online instrument, proactively alerting you to maintenance needs before your measurement becomes questionable. And a Hach Service Agreement protects your investment and helps ensure that you stay in compliance and on budget.

Includes

TU5300sc Turbidimeter, User Manual, Wall Mount, Vial Replacement Tool, Screw Set, Drying Cartridge, Flow Regulator, Service Bracket

Product Specifications

Communication System Check
Storage Conditions -40 - 60 °C (-40 - 140 °F)
Accuracy ±2% or 0.01 NTU from 0 - 40 NTU, ±10% of reading from 40 - 1000 NTU
Light source Class 2 laser product, with embedded 650 nm (EPA) or 850 nm (ISO)
Instrument Standard Process Head
Stray Light 10 mNTU
Response Time T90 45 seconds at 100 mL/min
Regulatory EPA
Warranty 12 months
Repeatability Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
 California residents see Prop 65 WARNINGS