Hach TU5200 Laboratory Laser Turbidimeter w/ out RFID, EPA Version, LPV442.99.01012

$5,664.00 | EA
Product #: 703594
Mfr. Part #: LPV442.99.01012

This item is in stock

Description

The platform employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test. For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection Technology in both instruments. The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on. The TU5200 Lab Turbidimeter, with the 360° x 90° Detection Technology, sees more of your sample meaning you no longer have to apply silicone oil to your vial and index to ensure an accurate reading. In addition, you can have confidence that you will get consistent results in the lab, from operator to operator, since the impact of small interferences is minimized due to the collection of light at 360°. Only the new TU 5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.

Features

  • The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.

  • For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection™ Technology in both instruments.

  • The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.

Includes

TU5200 benchtop turbidimeter, user manual, Stablcal kit (10, 20 and 600 NTU), 2 sample vials, power supply, dust cover, vial stand

Product Specifications

Display 7" WVGA (800 x 480) color TFT-LCD with touch screen
Repeatability 40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
Communication Link2sc
Storage Conditions -30 - 60 °C (-22 - 140 °F)
Accuracy ±2 % plus 0.01 NTU from 0 - 40 NTU; ±10 % of reading from 40 - 1000 NTU
Light source Class 2 laser product, with embedded 650 nm or Class 1 laser product, with embedded 850 nm (ISO)
Stray Light 10 mNTU
Source Lamp 650 nm Class 2 Laser
Response Time Signal averaging off: 7 seconds Signal averaging on: 10 seconds (when averaging time is 5 seconds)
Regulatory EPA
Warranty 12 months