Hach TL2300 Tungsten Lamp Turbidimeter, EPA, 0 - 4000 NTU, LPV444.99.00210

$3,879.00 | EA
Product #: 703599
Mfr. Part #: LPV444.99.00210

This item is in stock

Description

The new TL23 Series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding industrial and wastewater applications. Hach’s new TL23 lab turbidimeter brings a new face to the trusted legacy 2100N and 2100AN turbidimeters. It utilizes the same optic bloc while delivering an improved user experience with its intuitive interface, which ties perfectly to the rest of Hach’s laboratory instruments. Having the same optic bloc means that you can replace your old 2100N/AN with a TL23 turbidity meter without having to change any of your standard operating procedures. With their ratio technology, the TL23 lab turbidimeters are ideal for industrial and other samples with a wide range of turbidity. The main benefit of TL23’s ratio technology is that it helps to overcome the interference from large particles and color when measuring turbidity. Just like the legacy instrument, the TL23 lab turbidimeter comes in 4 different models: •2100N is replaced by TL2300 (EPA, up to 4,000NTU) •2100NIS is replaced by TL2310 (ISO, up to 1,000NTU) •2100AN is replaced by TL2350 (EPA, up to 10,000NTU) •2100ANIS is replaced by TL2360 (ISO, up to 10,000NTU)

Features

  • The TL23 Series’ large full color touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.

  • The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.

  • The TL23 Series provides everything you need at your fingertips, including a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance.

Includes

TL2300 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover

Product Specifications

Display 17.8 mm (7 in.) color touch screen
Repeatability ±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
Air Purge Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
Data logging 2000 total logs, includes reading log, verification log and calibration log
Communication USB
Storage Conditions -20 to 60 °C
Interface 2 USB-A ports for USB flash drive, external thermal printer, keyboard and barcode scanner
Accuracy Ratio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU
Light source Tungsten filament lamp
Stabilization Time Ratio on: 30 minutes after start-up Ratio off: 60 minutes after start-up
Source Lamp Tungsten Lamp
Sample Cell Compatibility Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps
Sample Requirements 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F)
Response Time Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds
Reading Modes Single, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off
Regulatory Meets EPA Method 180.1
Measurement Method Nephelometric
Warranty 12 months