Hach CLF10 sc Free Chlorine Analyzer (Panel Only) w/ pHD Differential Sensor, LXV45A.99.13022

$6,683.00 | EA
Product #: 703662
Mfr. Part #: LXV45A.99.13022

Out of Stock - Ships in 5-10 Days

Description

The CLF10 sc Free Chlorine Analyzer measures free chlorine continuously for real time process control. It is based on amperometric technology and is fully compatible with all of Hach's digital controllers. The CLF10 sc can be used in most municipal and industrial applications and is best utilized where waste stream management is a constraint. This analyzer is equipped with a pH sensor for use with the unique Cal Watch advanced diagnostic feature.

Features

  • The CLF10 sc and CLT10 sc analyzers leverage Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow.

  • Chlorine measurement with an amperometric analyzer, such as the CLF10 sc or CLT10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management.

  • The CLF10 sc and CLT10 sc analyzers allow for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed.

  • The CLF10 sc and CLT10 sc analyzers can be used with any Hach sc digital controller. Whether you're measuring turbidity or chlorine, you only need to learn one controller for all your water analysis measurement points. Hach sc controllers have no complicated wiring or setup procedures. Just plug in any Hach digital sensor and it's ready to use without software configuration.

  • In accordance with EPA Method 334.0, the CLF10 sc and CLT10 sc analyzers can be used for reporting chlorine residual measurements. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required in Method 334.0.

Includes

CL10 sc Panel, 1 m digital extension cable, Panel Manual, pHD Sensor Manual, Chlorine Sensor Manual.

Product Specifications

Repeatability 30 ppb or 3%, whichever is greater
Storage Conditions -20 °C to 60 °C dry
Interferences Free chlorine: monochloramine, chlorine dioxide, ozone, and chalk deposits.
Accuracy Free Chlorine: ± 3 % of the reference test* (DPD) at constant pH less than 7.2 (±0.2 pH unit)
Response Time Free Chlorine: 140 s or less for 90% change (T90) at a stable temperature and pH
Measurement Method Reagentless, electrochemical, three-electrode amperometric system
Parameters Free Chlorine
Warranty 12 months